PVC Insulated Wire & Twisted Pair (RVS / RVVP)
Twisted-pair flexible wire (RVS) for telephony / signalling and PVC insulated shielded wire (RVVP) for low-frequency signal and instrumentation.
Key Features
- RVS twisted pair for comms / doorbells
- RVVP with copper braid shield for signals
- Flexible, easy to terminate
Technical Specifications
PVC Insulated Wire & Twisted Pair (RVS / RVVP) — typical values
| Parameter | Specification |
|---|---|
| Rated voltage | 300/300 V (RVS), 300/500 V (RVVP) |
| Conductor | Cu, Class 5 flexible |
| Shield (RVVP) | Copper braid / aluminium foil |
Construction
- 01Flexible copper cores
- 02PVC insulation
- 03Twist (RVS)
- 04Shield + sheath (RVVP)
Applications
Telephony & signalling · Instrumentation · Alarm & control wiring
Power Distribution
Reliable energy transmission from source to endpoint
Construction & Building
CCC-certified wiring for safe, code-compliant buildings
Infrastructure & Public Works
Life-safety cables for metros, tunnels and public buildings
Energy Projects
Cables engineered for demanding energy sites
Standards & Compliance
Certificate copies are available on request — see Certifications.
Manufacturing Process
Stranding → PVC insulation → twist → (shield) → sheathing → testing.
Quality Inspection
- Conductor resistance
- Voltage withstand
- Shield continuity (RVVP)
Packaging & Shipping
Rolls per request.
Related Products
Further reading
Frequently Asked Questions
When is shielding needed?
RVVP shielding is used where the signal must be protected from electromagnetic interference in control and instrumentation circuits.
Official verification sources
The standards, directives and classification codes referenced on this site can be checked against these official texts. Document status is shown as published by the issuing body.
- European Commission / EUR-Lex— Directive 2014/35/EU (Low Voltage Directive), Article 1Official reference (document status, not our certification scope)official source ↗
- European Commission / EUR-Lex— Directive 2011/65/EU (RoHS), consolidated text 01/02/2024Official reference (document status, not our certification scope)official source ↗
- European Commission / EUR-Lex— Regulation (EU) No 305/2011 (Construction Products Regulation)In force (document status, not our certification scope)official source ↗
- International Electrotechnical Commission (IEC)— IEC 60502-1:2021, Edition 3.0, TC 20 (publication 64963)Official reference (document status, not our certification scope)official source ↗
- United Nations Statistics Division (UNSD)— Harmonized System 2017, heading 8544 and six-digit subheadingsOfficial classification data (document status, not our certification scope)official source ↗
- International Organization for Standardization (ISO)— ISO 9001:2015 — Quality management systems — Requirements, standard 62085Withdrawn edition (document status, not our certification scope)official source ↗
