LSZH Flame-Retardant & Fire-Resistant Power Cable
Low-smoke, halogen-free, flame-retardant (and fire-resistant) power cable for applications where life-safety and reduced smoke emission are critical — buildings, metros, tunnels, data centres and public infrastructure.

Product photo
LSZH Flame-Retardant & Fire-Resistant Power Cable
Low-smoke, halogen-free, flame-retardant (and fire-resistant) power cable for applications where life-safety and reduced smoke emission are critical — buildings, metros, tunnels, data centres and public infrastructure.
Key Features
- Low smoke, halogen-free sheath (LSZH polyolefin)
- Flame-retardant Class B1 / A and fire-resistant (NH) constructions
- Verified by accredited type tests (reports held on file)
- Reduced toxic and corrosive emission in fire
Technical Specifications
LSZH Flame-Retardant & Fire-Resistant Power Cable — typical values
| Parameter | Specification |
|---|---|
| Rated voltage U0/U | 0.6/1 kV |
| Conductor | Copper, Class 1 / Class 2 |
| Insulation | XLPE |
| Sheath | LSZH polyolefin |
| Burning behaviour | GB 31247 flame-retardant classes (B1 / A) |
| Fire resistance | IEC 60331 (where NH) |
Construction
- 01Copper conductor
- 02XLPE insulation
- 03Mica fire-resistant tape (NH)
- 04Filling
- 05LSZH sheath
Applications
Commercial & high-rise buildings · Metro & rail · Tunnels · Data centres · Public infrastructure
Power Distribution
Reliable energy transmission from source to endpoint
Construction & Building
CCC-certified wiring for safe, code-compliant buildings
Infrastructure & Public Works
Life-safety cables for metros, tunnels and public buildings
Energy Projects
Cables engineered for demanding energy sites
Renewable Energy
Solar and wind cabling for a cleaner grid
Standards & Compliance
Certificate copies are available on request — see Certifications.
Manufacturing Process
Conductor → XLPE insulation → mica tape (NH) → cabling → LSZH sheathing → testing.
Quality Inspection
- Conductor resistance
- Voltage withstand
- Flame-retardant / smoke density tests
- Fire-resistance test (NH)
Packaging & Shipping
Wooden drums, sealed ends.
Related Products
Further reading
Frequently Asked Questions
What is the difference between flame-retardant and fire-resistant?
Flame-retardant (WDZ) limits flame spread and smoke; fire-resistant (WDZN / NH) maintains circuit integrity for a defined period during fire.
Official verification sources
The standards, directives and classification codes referenced on this site can be checked against these official texts. Document status is shown as published by the issuing body.
- European Commission / EUR-Lex— Directive 2014/35/EU (Low Voltage Directive), Article 1Official reference (document status, not our certification scope)official source ↗
- European Commission / EUR-Lex— Directive 2011/65/EU (RoHS), consolidated text 01/02/2024Official reference (document status, not our certification scope)official source ↗
- European Commission / EUR-Lex— Regulation (EU) No 305/2011 (Construction Products Regulation)In force (document status, not our certification scope)official source ↗
- International Electrotechnical Commission (IEC)— IEC 60502-1:2021, Edition 3.0, TC 20 (publication 64963)Official reference (document status, not our certification scope)official source ↗
- United Nations Statistics Division (UNSD)— Harmonized System 2017, heading 8544 and six-digit subheadingsOfficial classification data (document status, not our certification scope)official source ↗
- International Organization for Standardization (ISO)— ISO 9001:2015 — Quality management systems — Requirements, standard 62085Withdrawn edition (document status, not our certification scope)official source ↗