XLPE Insulated Power Cable (YJV / YJLV)
Cross-linked polyethylene insulated, PVC sheathed power cable for fixed installation in power distribution networks, buildings, industry and infrastructure. Rated voltage 0.6/1 kV; construction and test requirements follow GB/T 12706 and IEC 60502-1.

Product photo
XLPE Insulated Power Cable (YJV / YJLV)
Cross-linked polyethylene insulated, PVC sheathed power cable for fixed installation in power distribution networks, buildings, industry and infrastructure. Rated voltage 0.6/1 kV; construction and test requirements follow GB/T 12706 and IEC 60502-1.
Key Features
- Rated voltage 0.6/1 kV with copper or aluminium conductors
- Operating temperature up to 90 °C (conductor), short-circuit 250 °C
- Higher current carrying capacity than equivalent PVC cables
- Available with steel-tape (22) or steel-wire (32) armour
- LSZH, flame-retardant (ZR) and fire-resistant (NH) versions available
Technical Specifications
XLPE Insulated Power Cable (YJV / YJLV) — typical values
| Parameter | Specification |
|---|---|
| Rated voltage U0/U | 0.6/1 kV |
| Conductor | Class 1 (solid) / Class 2 (stranded) copper or aluminium |
| Insulation | Cross-linked polyethylene (XLPE) |
| Sheath | PVC (ST5) or LSZH polyolefin |
| Max. conductor temp. (normal) | 90 °C |
| Max. conductor temp. (short-circuit) | 250 °C (≤5 s) |
| Bending radius | ≥ 15 × outer diameter (unarmoured) |
| Test voltage (AC, 5 min) | 3.5 kV |
Construction
- 01Conductor — copper (Cu) or aluminium (Al)
- 02XLPE insulation
- 03Filling / inner sheath (multi-core)
- 04Steel tape / steel wire armour (optional)
- 05PVC or LSZH outer sheath
Applications
Power distribution · Industrial plants · Commercial buildings · Infrastructure · Renewable energy sites
Power Distribution
Reliable energy transmission from source to endpoint
Construction & Building
CCC-certified wiring for safe, code-compliant buildings
Infrastructure & Public Works
Life-safety cables for metros, tunnels and public buildings
Energy Projects
Cables engineered for demanding energy sites
Renewable Energy
Solar and wind cabling for a cleaner grid
Standards & Compliance
Certificate copies are available on request — see Certifications.
Manufacturing Process
Conductor drawing and stranding → XLPE insulation by dry silane or CV process → colour coding → cabling / filling → sheathing (PVC or LSZH) → optional armouring → printing and testing.
Quality Inspection
- Conductor resistance test (GB/T 3956)
- Voltage withstand test 3.5 kV / 5 min
- Insulation / sheath thickness and overall dimensions
- Flame-retardant and fire-resistance tests where applicable
Packaging & Shipping
Delivered on wooden drums or steel-reinforced reels, wrapped against moisture; cable ends sealed. Custom drum sizes on request.
Related Products
Further reading
Frequently Asked Questions
What voltage ratings are available?
The YJV / YJLV range is supplied for 0.6/1 kV fixed-power distribution. Higher voltage classes can be discussed against your specification.
Can cables be supplied with LSZH or fire-resistant construction?
Yes. Flame-retardant (ZR) and fire-resistant (NH) low-smoke halogen-free versions are available and have been type-tested by accredited laboratories.
Are aluminium conductor versions offered?
Yes, YJLV aluminium-conductor power cables are offered from 10 mm² up to 400 mm².
Official verification sources
The standards, directives and classification codes referenced on this site can be checked against these official texts. Document status is shown as published by the issuing body.
- European Commission / EUR-Lex— Directive 2014/35/EU (Low Voltage Directive), Article 1Official reference (document status, not our certification scope)official source ↗
- European Commission / EUR-Lex— Directive 2011/65/EU (RoHS), consolidated text 01/02/2024Official reference (document status, not our certification scope)official source ↗
- European Commission / EUR-Lex— Regulation (EU) No 305/2011 (Construction Products Regulation)In force (document status, not our certification scope)official source ↗
- International Electrotechnical Commission (IEC)— IEC 60502-1:2021, Edition 3.0, TC 20 (publication 64963)Official reference (document status, not our certification scope)official source ↗
- United Nations Statistics Division (UNSD)— Harmonized System 2017, heading 8544 and six-digit subheadingsOfficial classification data (document status, not our certification scope)official source ↗